NZ 2400 Series Compact Vector Control
Power Range
Technical Specification
Items | Specification |
Standard Functions | |
Control Mode | V/F (Voltage/Frequency) Control Senseless flux vector control (VC) |
Maximum Frequency | Vector Control: 0-300 Hz; V/F Control: 0-3200 Hz |
Carrier Frequency | 1.0-16.0 kHz; The Carrier frequency is automatically adjusted based on the load features. |
Input Frequency Solution | Digital Setting: 0.01 Hz Analog Setting: 0.025% of maximum frequency |
Startup Torque | G type: 0.5 Hz/150% (VC) P type: 0.5 Hz/100% (VC) |
Speed range / stability accuracy | 1:100 (VC) / ± 0.2% (VC) |
Torque Control Accuracy | ± 20% |
Overload Capacity | G type: 60s for 150% of the rated current, 3s for 180% of the rated current. |
Torque Boost | Auto Boost Customized Boost 0.1% -30.0% |
V/F curve | Line V/F Curve Multi-point V/F Curve N-power V/F Curve (1.2-power, 1.4-power, 1.6 power, 1.8 power, square) |
V/F Separation | Two Types: complete separation; half separation |
Ramp Mode | Straight-line Ramp; S-curve ramp Four groups of acceleration/deceleration time with the range of 0.0-6500.0s |
Standard Functions | |
DC Braking | DC Braking Frequency: 0.00Hz to maximum frequency Braking Time: 0.0-100.0s; Braking action current value: 0.0%-100.0% |
JOG Control | JOG frequency range: 0.00-50.00 Hz JOG acceleration/deceleration time: 0.0-6500.0s |
Onboard multiple preset speeds | It implements up to 16 speeds via the simple PLC function or combination of terminal states |
Onboard PID | It realizes process-contolled closed loop control system easily. |
Auto Voltage Regulation (AVR) | It can kep constant output voltage automatically when the mains voltage changes. |
Overvoltage/ Overcurrent stall control | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvolatge/over Current. |
Torque limit & control | It can limit the torque automatically and prevent frequent over current tripping during the running process |
Power dip ride through | The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time. |
Rapid Current Limit | It helps to avoid frequent over current faults of the AC drive. |
Rapid Current Limit | It helps to avoid frequent over current faults of the AC drive. |
High Performance | Control of asynchronous motoris implemented through the high performance current vector technology |
Timing Control | Time range: 0.0-6500.0 minutes |
Communication methods | Rs485 (MODBUS-RTU) |
Protection mode | Motor short-circuit detection at power-on, input/output phase loss protection, over current protection, overvolatge protection, under voltage protection, overheat protection and overload protection. |
Input and Output | |
Input terminal | 6 Digital Input Terminals, one of which supports up to 100 kHz high-speedpulse input. 2 analog input terminals, one of which only supports 0-10 V voltage input and the other supports 0-10 V voltage input or 4-20 mA current input. |
Frequency Source | Digital Setting, Analog voltage setting, analog current setting, pulse setting and serial communication port setting |
Auxiliary Frequency Source | There are ten auxiliary frequency sources. It can implement fine tuning of auxiliary frequency and frequency synthesis. |
Running Command Source | Operation panel/Control terminals/Serial communication port. You can perform switchover between these sources in various ways. |
Output Terminal | 1 Digital output terminal; 1 relay output terminal 1 analog output terminal :that supports 0-20 mA current output or 0-10 V voltage output |
LED Display | It displays the parameters. |
Key Locking and function selection | It can lock the keys partially or completely and define the function range of some keys so as to prevent mis-function. |