E102 General Series Inverter
Power Range
Technical Specification
Item | Specification | |
Control | Control mode | V/F Control Open-loop Vector Control (SVC) |
Frequency Resolution | Digital quantity: 0.02% Analog quantity: 0.1% | |
V/F curve | Linear, square root, random V/F | |
Overload capability | G Model: 150% rated current: 60s; 180% rated current: 3s | |
P Model: 120% rated current: 60s; 150% rated current: 3s | ||
Starting torque | G Model:0.5Hz/150% (SVC); 0Hz/180% (VC) | |
P Model:0.5Hz/100% | ||
Speed regulation range | 1:100(SVC) 1:1000(VC) | |
Stable speed accuracy | ±0.5%(SVC) ±0.02%(VC) | |
Torque control accuracy | ±5%(VC) | |
Torque compensation | Manual torque compensation (0.1%~30.0%), auto torque compensation | |
Configuration | Control power supply +24V | Max. Output Current 300mA without current-limiting protection |
Input terminal | 5-way Digital Input Terminal (DI1~DI6), in which D16 can access to high-speed Impulse Input (only internal power supply is available) 2-way Analog Input Terminal (VF1, VF2), which can be used as voltage (0V~10V) or current (0/4mA~20mA) input. It can be used as Digital Input Terminal through reference. | |
Output terminal | 1-way Analog Input Terminal FM1, which can not only be used as output voltage (0V~10V),but output current (0mA~20mA). 1-way Relay Output T1, DC 30V/3A below and AC 250V/3A below | |
Running | Running mode | Keyboard, terminal, RS485 communication |
Frequency source | 14 kinds of main frequency sources and 14 kinds of auxiliary sources. Adopt various combination modes to switch. Diversification to Each Frequency Source Input Mode: keyboard potentiometer, external analog, digital reference, impulse reference, Multiplex Directive, simple PLC, communication, arithmetic results, etc. | |
Torque source | 14 kinds of Torque Sources, including digital reference, external analog, impulse reference, Multiplex Directive, communication, arithmetic results, etc. | |
Acceleration/deceleration time | Four groups of straight lines (select the terminal to switch through acceleration and deceleration time), S Curve 1 and S Curve 2 | |
Emergency stop | Interrupt output of frequency inverter. | |
Multiplex Speed | 16 speed is allowable to set at most and use various combination of multiplex directive terminal to switch | |
Simplified PLC function | Continuously run 16-phase speed and independently set acceleration and deceleration time and running time | |
Jogging Control | Independently set Jogging frequency and jogging acceleration and deceleration time, additionally, set the unit under running state and confirm whether the jogging is preferential | |
Rotating Speed Tracking | Frequency inverter starts operation by tracking the load speed | |
Fixed-length and Fixed-distance | Control Realize fixed-length and fixed-distance control function through Impulse Input |